NIST REFPROP Database Skill

Query high-accuracy thermodynamic and transport properties using the NIST REFPROP (Reference Fluid Thermodynamic and Transport Properties) database - the gold standard for thermophysical property calculations.

Overview

NIST REFPROP is a commercial-grade thermophysical property database developed by the National Institute of Standards and Technology (NIST). It provides:

  • Pure Fluids: 147+ pure fluids with the highest available accuracy
  • Mixtures: Predefined and custom mixtures with advanced mixing rules
  • Refrigerant Blends: All common refrigerant blends with temperature glide
  • Transport Properties: Viscosity, thermal conductivity, surface tension
  • Thermodynamic Properties: Enthalpy, entropy, density, specific heat
  • Phase Equilibrium: VLE, LLE, VLLE calculations for mixtures
  • Highest Accuracy: Reference-quality data validated against experimental measurements

REFPROP is the industry and research standard for:

  • Critical engineering design requiring highest accuracy
  • Validation of other property libraries (CoolProp is validated against REFPROP)
  • Mixture calculations with complex phase behavior
  • Refrigerant blend applications with temperature glide
  • Research and publication-quality data

Licensing

COMMERCIAL LICENSE REQUIRED

NIST REFPROP is NOT free or open-source software. You must purchase a license from NIST:

License includes:

  • REFPROP software (Windows GUI)
  • Fluid database files
  • Excel add-in
  • FORTRAN/DLL libraries
  • Python wrapper compatibility

Important Notes:

  • License is per-user, perpetual (one-time fee)
  • Updates and new fluid files provided for ~5 years
  • Required for commercial applications
  • Cannot be redistributed

Installation

Step 1: Purchase and Install REFPROP

  1. Purchase REFPROP license from NIST: https://www.nist.gov/srd/refprop
  2. Download and install REFPROP (typically to C:\Program Files (x86)\REFPROP\)
  3. Note the installation directory path

Step 2: Install Python Wrapper

pip install ctREFPROP

The ctREFPROP package provides a Python interface to REFPROP using ctypes.

Step 3: Set RPPREFIX Environment Variable

The Python wrapper needs to know where REFPROP is installed:

Windows:

# PowerShell
$env:RPPREFIX = "C:\Program Files (x86)\REFPROP\"

# Or set permanently via System Properties > Environment Variables

Linux/Mac:

export RPPREFIX="/path/to/REFPROP/"

Python (alternative):

import os
os.environ['RPPREFIX'] = r'C:\Program Files (x86)\REFPROP'

Step 4: Verify Installation

from ctREFPROP.ctREFPROP import REFPROPFunctionLibrary

# Initialize REFPROP
RP = REFPROPFunctionLibrary(os.environ['RPPREFIX'])
RP.SETPATHdll(os.environ['RPPREFIX'])

# Test query
print(RP.RPVersion())

Available Fluids

REFPROP includes 147+ pure fluids organized by class:

Common Industrial Fluids

  • Water (H₂O) - IAPWS-95 formulation
  • Air - Dry air mixture
  • Carbon Dioxide (CO₂)
  • Nitrogen (N₂)
  • Oxygen (O₂)
  • Argon (Ar)
  • Helium (He)
  • Hydrogen (H₂)

Hydrocarbons (40+ fluids)

  • Alkanes: Methane, Ethane, Propane, Butane, Pentane, Hexane, Heptane, Octane, Nonane, Decane (and isomers)
  • Alkenes: Ethylene, Propylene, Butene
  • Aromatics: Benzene, Toluene, Xylenes
  • Cyclic: Cyclohexane, Cyclopentane

Refrigerants (60+ fluids)

  • CFCs: R11, R12, R13, R113, R114, R115
  • HCFCs: R22, R123, R124, R141b, R142b
  • HFCs: R23, R32, R125, R134a, R143a, R152a, R227ea, R236fa, R245fa, R365mfc
  • HFOs: R1234yf, R1234ze(E), R1233zd(E), R1336mzz(Z)
  • Natural: R717 (Ammonia), R744 (CO₂), R290 (Propane), R600a (Isobutane)
  • Blends: R404A, R407C, R410A, R507A, R407F, R448A, R449A, R450A, R513A

Cryogenic Fluids

  • Helium, Neon, Argon, Krypton, Xenon
  • Hydrogen, Deuterium, Parahydrogen
  • Nitrogen, Oxygen, Fluorine
  • Methane, Ethane (LNG components)

Specialty Fluids

  • Siloxanes: D4, D5, D6, MD2M, MD3M, MD4M, MDM, MM (ORC applications)
  • Alcohols: Methanol, Ethanol, Propanol, Butanol
  • Other Organics: Acetone, Benzene, Toluene
  • Inorganics: Ammonia, Sulfur dioxide, Hydrogen sulfide

See reference.md for complete fluid list.

Property Queries

Core Functions

REFPROP uses different function calls than CoolProp:

from ctREFPROP.ctREFPROP import REFPROPFunctionLibrary
import os

# Initialize
RP = REFPROPFunctionLibrary(os.environ['RPPREFIX'])
RP.SETPATHdll(os.environ['RPPREFIX'])

# Define fluid
MOLAR_BASE_SI = RP.GETENUMdll(0, "MOLAR BASE SI").iEnum
fluid = "WATER"

# Single component
r = RP.REFPROPdll(fluid, "TP", "D;H;S;CP;CV;W;VIS;TCX", MOLAR_BASE_SI, 0, 0, 298.15, 101.325, [1.0])

# Access results
density = r.Output[0]      # kg/m³
enthalpy = r.Output[1]     # J/kg
entropy = r.Output[2]      # J/kg/K
cp = r.Output[3]           # J/kg/K
cv = r.Output[4]           # J/kg/K
sound_speed = r.Output[5]  # m/s
viscosity = r.Output[6]    # Pa·s
conductivity = r.Output[7] # W/m/K

Input Specifications

Code Property Unit
TP Temperature, Pressure K, kPa
TH Temperature, Enthalpy K, J/kg
TS Temperature, Entropy K, J/kg/K
TD Temperature, Density K, kg/m³
PH Pressure, Enthalpy kPa, J/kg
PS Pressure, Entropy kPa, J/kg/K
PD Pressure, Density kPa, kg/m³
TQ Temperature, Quality K, -
PQ Pressure, Quality kPa, -

Output Properties

Code Property Unit
D Density kg/m³
H Enthalpy J/kg
S Entropy J/kg/K
U Internal energy J/kg
CP Heat capacity (const P) J/kg/K
CV Heat capacity (const V) J/kg/K
W Speed of sound m/s
VIS Viscosity Pa·s
TCX Thermal conductivity W/m/K
KV Kinematic viscosity m²/s
PRANDTL Prandtl number -
STN Surface tension N/m
P Pressure kPa
T Temperature K
Q Quality (vapor fraction) -

Multiple properties can be requested in one call, separated by semicolons: "D;H;S;CP;VIS;TCX"

Mixture Calculations

One of REFPROP's key advantages is sophisticated mixture handling:

# Define mixture by components and mole fractions
fluid = "METHANE;ETHANE;PROPANE"
z = [0.9, 0.07, 0.03]  # Mole fractions (must sum to 1.0)

# Query mixture properties
r = RP.REFPROPdll(fluid, "TP", "D;H;S", MOLAR_BASE_SI, 0, 0, 250.0, 5000.0, z)

Mixture Features:

  • Up to 20 components in a mixture
  • Advanced mixing rules (GERG-2008, Kunz-Wagner, etc.)
  • Temperature glide calculations for zeotropic blends
  • Vapor-liquid equilibrium (VLE) calculations
  • Liquid-liquid equilibrium (LLE) for certain systems

Advantages Over CoolProp

While CoolProp is excellent and free, REFPROP offers:

1. Higher Accuracy

  • REFPROP is the reference standard that other libraries validate against
  • More precise equations of state, especially near critical point
  • Better transport property correlations
  • Typical accuracy: 0.01% for density vs 0.1% for CoolProp

2. More Fluids

  • 147+ pure fluids vs ~120 in CoolProp
  • All latest refrigerants (HFOs: R1234yf, R1234ze, R1233zd, etc.)
  • More industrial and specialty chemicals
  • Frequently updated with new fluids

3. Better Mixture Handling

  • Superior mixing rules (GERG-2008, advanced models)
  • Handles complex non-ideal mixtures
  • Temperature glide for zeotropic refrigerant blends
  • VLE/LLE calculations
  • Up to 20 components vs limited mixture support in CoolProp

4. Extended Property Range

  • Valid over wider temperature and pressure ranges
  • Better extrapolation behavior
  • More reliable in extreme conditions

5. Additional Capabilities

  • Humidity calculations (psychrometrics)
  • Flash calculations (PT, PH, PS, etc.)
  • Saturation properties with Jacobian
  • Ancillary equations
  • Pseudo-pure fluid approximations

6. Official Support

  • Maintained by NIST (National Institute of Standards and Technology)
  • Technical support available
  • Regular updates with latest research
  • Publication-quality results

When to Use REFPROP vs CoolProp

Use REFPROP when:

  • Highest accuracy is required (±0.01%)
  • Working with complex mixtures
  • Need latest refrigerant data (HFOs)
  • Publication or critical design work
  • Budget allows commercial license
  • Working with zeotropic blends (temperature glide)

Use CoolProp when:

  • Budget constraints (free/open-source)
  • Basic property needs (±0.1% accuracy acceptable)
  • Pure fluids only
  • Open-source license required
  • Quick prototyping

Validation Note: CoolProp is validated against REFPROP, confirming REFPROP as the reference standard.

Common Workflow Example

from ctREFPROP.ctREFPROP import REFPROPFunctionLibrary
import os

# Setup
os.environ['RPPREFIX'] = r'C:\Program Files (x86)\REFPROP'
RP = REFPROPFunctionLibrary(os.environ['RPPREFIX'])
RP.SETPATHdll(os.environ['RPPREFIX'])

MOLAR_BASE_SI = RP.GETENUMdll(0, "MOLAR BASE SI").iEnum

# Query water at 25°C, 1 bar
fluid = "WATER"
T = 298.15  # K
P = 100.0   # kPa

r = RP.REFPROPdll(fluid, "TP", "D;H;S;CP;VIS;TCX", MOLAR_BASE_SI, 0, 0, T, P, [1.0])

print(f"Water at {T} K, {P} kPa:")
print(f"  Density: {r.Output[0]:.4f} kg/m³")
print(f"  Enthalpy: {r.Output[1]:.2f} J/kg")
print(f"  Entropy: {r.Output[2]:.2f} J/kg/K")
print(f"  Cp: {r.Output[3]:.2f} J/kg/K")
print(f"  Viscosity: {r.Output[4]*1000:.4f} mPa·s")
print(f"  Conductivity: {r.Output[5]:.4f} W/m/K")

Error Handling

REFPROP returns error codes and messages:

r = RP.REFPROPdll(fluid, "TP", "D", MOLAR_BASE_SI, 0, 0, T, P, z)

if r.ierr > 0:
    print(f"Error {r.ierr}: {r.herr}")
elif r.ierr < 0:
    print(f"Warning {r.ierr}: {r.herr}")
else:
    print(f"Success: {r.Output[0]}")

Units

REFPROP uses different unit conventions than CoolProp:

Default Units (with MOLAR BASE SI):

  • Temperature: K (Kelvin)
  • Pressure: kPa (kilopascals) - Note: CoolProp uses Pa
  • Density: kg/m³
  • Enthalpy: J/kg
  • Entropy: J/kg/K
  • Viscosity: Pa·s
  • Thermal conductivity: W/m/K

Unit Systems Available:

  • SI with molar units
  • SI with mass units (default shown above)
  • English units
  • Custom units

Best Practices

  1. Always set RPPREFIX before importing ctREFPROP
  2. Check ierr for errors after each call
  3. Use exact fluid names (case-sensitive, from FLUIDS directory)
  4. Pre-calculate compositions for mixtures (must sum to 1.0)
  5. Cache RP instance - don't reinitialize repeatedly
  6. Use appropriate input pairs for each phase region
  7. Validate results against known values initially
  8. Read error messages - REFPROP provides detailed diagnostics

References

Official Resources

  1. NIST REFPROP Website

  2. REFPROP Documentation

    • Included with installation
    • REFPROP.pdf in installation directory
  3. ctREFPROP Documentation

Key Publications

  • Lemmon, E.W., Bell, I.H., Huber, M.L., McLinden, M.O. (2018). "NIST Standard Reference Database 23: Reference Fluid Thermodynamic and Transport Properties-REFPROP, Version 10.0", National Institute of Standards and Technology.

Support

Quick Reference

# Initialize
from ctREFPROP.ctREFPROP import REFPROPFunctionLibrary
RP = REFPROPFunctionLibrary(os.environ['RPPREFIX'])
RP.SETPATHdll(os.environ['RPPREFIX'])
MOLAR_BASE_SI = RP.GETENUMdll(0, "MOLAR BASE SI").iEnum

# Pure fluid
r = RP.REFPROPdll("WATER", "TP", "D;H;S", MOLAR_BASE_SI, 0, 0, 300.0, 101.325, [1.0])

# Mixture
r = RP.REFPROPdll("METHANE;ETHANE", "TP", "D;H;S", MOLAR_BASE_SI, 0, 0, 200.0, 5000.0, [0.9, 0.1])

# Check for errors
if r.ierr != 0:
    print(f"Error/Warning: {r.herr}")

NIST REFPROP is the gold standard for thermophysical properties. While it requires a commercial license, the investment is justified for applications requiring the highest accuracy, mixture calculations, or publication-quality results. For open-source alternatives, see the coolprop-db skill.