openshift-cluster-upgrade

star 7

Plan and troubleshoot OpenShift cluster upgrades with focus on irreversibility, upgrade-path validation, and stuck-upgrade diagnosis.

redhat-community-ai-tools By redhat-community-ai-tools schedule Updated 6/7/2026

name: openshift-cluster-upgrade description: Plan and troubleshoot OpenShift cluster upgrades with focus on irreversibility, upgrade-path validation, and stuck-upgrade diagnosis.

OpenShift Cluster Upgrade

Critical: Upgrades Are Irreversible

OpenShift cluster upgrades cannot be rolled back. There is no "undo." The only recovery from a catastrophically failed upgrade is restoring from an etcd backup, which requires full cluster downtime and loses all changes made after the backup. Prevention is everything — every section below exists to prevent you from starting an upgrade that will fail.

Pre-Upgrade Gate Checks

Do NOT proceed unless ALL of these pass:

  1. All ClusterOperators healthy: AVAILABLE=True, PROGRESSING=False, DEGRADED=False for every CO. A single degraded operator can block the upgrade partway through.
  2. All nodes Ready: A NotReady node will block MCP rollout and stall the upgrade.
  3. No critical alerts firing: Check Prometheus/AlertManager — active alerts often indicate problems that will worsen during upgrade.
  4. Sufficient resource headroom: Nodes need spare capacity because pods are evicted and rescheduled one node at a time during worker updates. If the cluster is already at capacity, pods will have nowhere to go.
  5. Certificates not expiring soon: Expired certs during upgrade cause cascading failures. Check CSRs and certificate secrets.
  6. etcd backup taken: Since upgrades are irreversible, an etcd snapshot is your only safety net.

If any gate fails, fix it first. Starting an upgrade on a degraded cluster compounds problems.

Upgrade Path Decision

  • Standard: Set the channel (stable-4.x), run oc adm upgrade, pick the target version. This is the happy path.
  • EUS-to-EUS: Extended Update Support lets you skip intermediate minor versions, but it's a TWO-HOP process. Example: 4.14 EUS → 4.15 (intermediate) → 4.16 EUS. You must fully complete the first hop before starting the second.
  • Large clusters: Pause the worker MachineConfigPool before upgrading (oc patch mcp worker --type merge -p '{"spec":{"paused":true}}'). This lets the control plane update first. Then unpause workers in batches by unpausing one MCP at a time or by using node selectors. This prevents all workers from draining simultaneously.
  • Air-gapped: Mirror the release images to your internal registry first, create an ImageContentSourcePolicy, then upgrade with --to-image pointing to the mirrored image.

What Happens During an Upgrade (Three Phases)

  1. CVO updates cluster operators: Downloads new release image, rolls out updated operators. Watch with oc get co.
  2. Control plane nodes update: API servers, controller managers, schedulers update one control plane node at a time. Brief API unavailability is normal.
  3. Worker nodes update: MachineConfigOperator renders new configs, nodes drain and reboot one at a time. This is the slowest phase. Watch with oc get mcp — UPDATED=True, UPDATING=False, DEGRADED=False means complete.

Stuck Upgrade Diagnosis

Follow this priority chain — each step is the most likely cause at that point:

  1. Check clusterversion conditions: oc describe clusterversion — the status conditions usually contain the actual error message explaining what's blocked
  2. Find the degraded ClusterOperator: oc get co — look for DEGRADED=True or AVAILABLE=False. This is the blocker ~60% of the time
  3. Check MCP state: oc get mcp — if worker or master pool shows DEGRADED=True, a node failed to apply the new machine config
  4. Check for nodes that won't drain: A node stuck in SchedulingDisabled with pods still running means drain is blocked. Check for PodDisruptionBudgets (oc get pdb -A) that prevent eviction — a PDB with maxUnavailable: 0 will block drain forever
  5. Check machine-config-daemon on the stuck node: If MCP is degraded, the machine-config-daemon log on the specific node usually has the error. Use oc logs -n openshift-machine-config-operator with the node-specific daemon pod
  6. Force drain as last resort: Only for decommission scenarios. Force drain loses data in emptyDir volumes and ignores PDBs

Gotchas

  • --force on oc adm upgrade bypasses version-graph safety checks. It does NOT force a stuck upgrade to continue. Almost never correct.
  • --allow-explicit-upgrade is only for upgrading to versions not in the recommended graph. Don't use it for normal upgrades.
  • Worker node updates are intentionally slow (one node at a time). A 20-node cluster can take 2+ hours for the worker phase alone. Don't panic at slow progress.
  • oc adm upgrade --clear cancels a pending upgrade but does NOT revert changes already applied. Use only if the upgrade hasn't started yet.
  • If the upgrade started but stalled, you must fix the blocker and let it continue — you cannot cancel mid-upgrade.

When to Use Sibling Skills

  • ClusterOperator degraded during upgrade → use openshift-operator-troubleshooting to diagnose the specific operator
  • Node won't drain or is NotReady → use openshift-node-operations for drain/node diagnosis
  • General cluster health investigation pre-upgrade → use openshift-debugging for triage