inspection-tracker

star 1

Track inspections and permits through the construction lifecycle. Handles scheduling, result logging, re-inspection tracking, permit management, and status reporting. Healthcare-specific: state health dept inspections, life safety, ADA compliance. PEMB-specific: anchor bolt, high-strength bolt, moment connection special inspections. Integrates with morning brief and look-ahead. Triggers: "inspection", "schedule inspection", "log inspection", "inspection status", "permit", "failed inspection", "re-inspect", "upcoming inspections", "special inspection".

mgoodman60 By mgoodman60 schedule Updated 2/25/2026

name: inspection-tracker description: > Track inspections and permits through the construction lifecycle. Handles scheduling, result logging, re-inspection tracking, permit management, and status reporting. Healthcare-specific: state health dept inspections, life safety, ADA compliance. PEMB-specific: anchor bolt, high-strength bolt, moment connection special inspections. Integrates with morning brief and look-ahead. Triggers: "inspection", "schedule inspection", "log inspection", "inspection status", "permit", "failed inspection", "re-inspect", "upcoming inspections", "special inspection". version: 1.0.0

Inspection Tracker Skill

Overview

The Inspection Tracker skill manages all construction inspections and permits throughout the project lifecycle. It provides real-time scheduling, result logging, re-inspection workflows, permit tracking, and comprehensive status reporting with integration into daily project management routines.

Data Model

Inspection Object

{
  "id": "INSP-001",
  "type": "Concrete Pre-placement",
  "date_scheduled": "2025-03-15T09:00:00Z",
  "date_completed": null,
  "inspector": "John Smith",
  "result": null,
  "notes": "",
  "deficiencies": [],
  "re_inspection_required": false,
  "re_inspection_id": null,
  "linked_schedule_activity": "SAC-042",
  "linked_hold_point": "HP-08",
  "linked_spec_section": "03 30 00",
  "location": "Building A, Level 2",
  "photos": [],
  "status": "scheduled"
}

Fields:

  • id: Unique identifier (INSP-001, INSP-002, etc.)
  • type: Inspection classification (see Standard & Special Inspection Types)
  • date_scheduled: ISO 8601 timestamp
  • date_completed: Completion timestamp; null if not yet completed
  • inspector: Name of inspector; external if not in approved list
  • result: pass, fail, conditional, cancelled, or null if pending
  • notes: Detailed observations, findings, or cancellation reason
  • deficiencies: Array of identified issues requiring correction (if result = fail)
  • re_inspection_required: Boolean; true if result = fail
  • re_inspection_id: Reference to linked re-inspection (INSP-NNN)
  • linked_schedule_activity: Schedule activity ID for smart linking (e.g., SAC-042)
  • linked_hold_point: Spec hold point reference (e.g., HP-08)
  • linked_spec_section: CSI specification section (e.g., 03 30 00)
  • location: Physical location (room, area, grid reference)
  • photos: Array of photo file paths or URLs for evidence
  • status: scheduled, completed, cancelled, hold (awaiting prerequisites)

Permit Object

{
  "id": "PERMIT-001",
  "type": "Building Permit",
  "number": "BP-2025-4521",
  "date_applied": "2025-02-01",
  "date_issued": "2025-02-20",
  "expiration": "2026-02-20",
  "jurisdiction": "City Building Department",
  "status": "active",
  "conditions": ["Final inspection before occupancy", "Weekly inspection during excavation"],
  "inspections_required": ["INSP-001", "INSP-003"],
  "notes": ""
}

Fields:

  • id: Unique identifier (PERMIT-001, PERMIT-002, etc.)
  • type: Permit classification
  • number: Official permit number
  • date_applied: Application submission date
  • date_issued: Date permit was issued; null if pending
  • expiration: Expiration date for renewal tracking
  • jurisdiction: Issuing authority
  • status: applied, issued, active, expired, renewed
  • conditions: Array of permit conditions or special requirements
  • inspections_required: Array of inspection IDs required per permit
  • notes: Additional remarks or tracking notes

Standard Inspection Types

ID Type Typical Spec Section Hold Point Notes
01 Foundation 03 11 00 HP-01 Before concrete placement
02 Concrete Pre-placement 03 30 00 HP-02 Rebar, formwork, reinforcement
03 Rebar 03 20 00 HP-03 Size, spacing, cover verification
04 Formwork 03 10 00 HP-04 Structural adequacy, bracing
05 Structural Steel 05 12 00 HP-05 Connections, bolt torque, straightness
06 Underground Utilities 33 00 00 HP-06 Location, depth, protection
07 Electrical 26 00 00 HP-07 Rough-in, panel installation, grounding
08 Plumbing 22 00 00 HP-08 Rough-in, pressure test, slope
09 Mechanical 23 00 00 HP-09 Equipment installation, ductwork
10 Fire Protection 21 00 00 HP-10 Sprinkler lines, device placement
11 Insulation 07 21 00 HP-11 R-value verification, continuity
12 Fireproofing 07 81 00 HP-12 Applied thickness, coverage
13 Final 01 77 00 HP-13 Walk-through, punch list generation

Healthcare-Specific Inspections

Type Trigger Requirement Notes
Life Safety Continuous Code compliance ADA accessibility, egress paths, alarm systems
ADA Compliance Pre-occupancy Americans with Disabilities Act Ramps, doors, restrooms, signage
State Health Dept Final Health Dept approval Medical gas outlets, emergency systems, infection control
Infection Control Pre-occupancy Special protocols HVAC testing, surface finishes, hand hygiene stations

PEMB-Specific Special Inspections

Pre-Engineered Metal Building (PEMB) requires specialized inspections per AWS D1.1 and manufacturer specs:

Type Tolerance Requirement Notes
Anchor Bolt ±1/8" Location & elevation Grid reference, hold-down torque verification
High-Strength Bolt ±1/32" Proper tension Calibrated wrench, bolt grade certification
Moment Connection ±1/4" Beam-to-column welds 100% visual + UT inspection required

Special Inspection IDs: INSP-PEMB-001, INSP-PEMB-002, etc.

Auto-Linking Intelligence

The inspection-tracker skill automatically links inspections to project intelligence:

Schedule Activity Linking

Query project intelligence for schedule activities matching inspection date and type:

  • "Concrete Pour Day" → auto-link to concrete pre-placement inspection
  • "Steel Erection Week 3" → auto-link to structural steel inspection
  • "Electrical Rough-In Phase" → auto-link to electrical inspection

Hold Point Linking

Cross-reference spec hold points from project spec database:

  • Inspection type matched to standard hold point (HP-02, HP-05, etc.)
  • Override if project-specific hold point defined
  • Display linked hold point ID to superintendent

Specification Section Linking

Auto-populate CSI specification section reference:

  • Foundation → 03 11 00
  • Concrete → 03 30 00
  • Structural Steel → 05 12 00
  • Electrical → 26 00 00

Hold Point Auto-Population

Read specs-quality.jsonhold_points[] → match inspection type to hold point by work_type:

  • Pull the hold point's inspection_name, trigger condition, inspector, and spec_reference
  • Auto-populate the inspection's linked_hold_point and linked_spec_section fields
  • Example: Scheduling "Concrete Pre-placement" → match hold_points where work_type contains "Concrete" → auto-link HP-02 with trigger "Before concrete placement" and spec reference

Weather Threshold Check

Before scheduling outdoor inspections:

  • Read specs-quality.jsonweather_thresholds[] → match by the inspection's work type
  • Cross-check forecasted weather against min_temp, max_temp, max_wind, and moisture_ok
  • Flag if weather conditions may prevent the inspection or the underlying work (e.g., concrete pour inspection + temp < 40°F cold weather threshold)
  • Include mitigation measures from the spec when flagging

Spec Section Deep-Link

When an inspection type is identified:

  • Read specs-quality.jsonspec_sections[] → find the matching CSI section
  • Pull specific testing requirements (frequency, type, agency), acceptance criteria from key_req, and required documentation
  • Auto-populate inspection notes with testing protocol and acceptance criteria
  • Example: Compaction inspection → pull "95% modified Proctor, testing every 500 CY" from spec section

Schedule Activity Linking (Enhanced)

  • Read schedule.jsoncritical_path[] and milestones[] → match inspection date/type to schedule activities
  • Auto-link inspection to schedule activity and flag if the activity is on the critical path
  • If critical path: add note "Critical path activity — inspection delay will impact project completion"

Drawing Reference

When inspection location is identified:

  • Read plans-spatial.jsonsheet_cross_references.drawing_index[] → find relevant structural/MEP drawings for the inspection location and discipline
  • Include referenced sheet numbers in inspection record for field use
  • Example: Foundation inspection at Grid C-3 → reference sheets S2.1, S5.1

Re-Inspection Workflow

When inspection result = fail:

  1. Create Re-Inspection Entry:

    • Auto-generate new INSP ID (sequential)
    • Set type as "{Original Type} (Re-inspection)"
    • Set related_to field to original inspection ID
    • Suggest date 48 hours after deficiency notification
  2. Track Deficiencies:

    • Collect detailed deficiency descriptions
    • Log which contractor responsible for correction
    • Reference section of spec violated
    • Attach photos of deficiency
  3. Notification:

    • Alert responsible trade contractor
    • Flag in morning brief
    • Include in daily report until re-inspection passed
  4. Closure:

    • Log re-inspection result
    • Document corrective action taken
    • Release hold if pass
    • Create additional re-inspection if still fail

Permit Tracking & Expiration Alerts

Auto-Alert Thresholds:

  • 30 days to expiration: Yellow flag in status report; suggest renewal inquiry
  • 7 days to expiration: Red flag; escalate to project manager
  • Expired: Red flag; mark status as expired; notify responsible party

Renewal Workflow:

  • Track date application submitted for renewal
  • Update status to renewed upon reissuance
  • Maintain continuous permit coverage throughout project

Integration Points

Morning Brief (/morning-brief)

Display under "Inspections & Permits" section:

  • Upcoming inspections (next 24 hours) — show type, time, location, inspector
  • Overdue inspections (no result logged) — Red flag with days overdue
  • Permits expiring within 30 days — Yellow alert with days remaining

Look-Ahead Schedule (/look-ahead)

Include scheduled inspections in weekly look-ahead:

  • Inspections integrated by date into weekly view
  • Show impact on critical path if hold point inspection
  • Cross-reference with material delivery/contractor schedule
  • Highlight PEMB special inspections with bold/asterisk

Daily Report (/daily-report)

Section: "Inspections Today"

  • Scheduled inspections for the day (time, type, location, inspector)
  • Completed inspections from previous day (result, notes summary)
  • Pending re-inspections affecting schedule
  • Permit status reminder (expiring within 14 days)

Error Handling & Validation

  • Duplicate Re-inspection: Warn if re-inspection already exists for same deficiency
  • Invalid Inspector: Log "External Inspector" if not in approved list; alert PM
  • Missing Linked Activity: Alert if schedule activity cannot be found; allow manual entry
  • Permit Conflict: Warn if inspection scheduled outside permit scope
  • Date Validation: Reject inspection scheduled before permit issued
  • Status Consistency: Prevent result logging if status ≠ scheduled

Triggers & Voice Commands

  • "Schedule an inspection"
  • "Log inspection INSP-042"
  • "Show inspection status"
  • "What inspections are overdue?"
  • "Upcoming inspections?"
  • "Schedule a rebar inspection for Monday"
  • "Inspection failed — need re-inspection"
  • "Track permits"
  • "When does the building permit expire?"
  • "Special inspection — anchor bolts"
  • "Healthcare inspection — state health dept"

Safety Incident Cross-Reference

For safety incidents discovered during inspections, route to the safety-management skill for incident documentation, root cause analysis (5-Why, Fishbone), OSHA recordkeeping (300/300A/301), and corrective action tracking. Write incident data to safety-log.json, not inspection-log.json.

When an inspection failure reveals a safety concern:

  1. Log the inspection result normally in inspection-log.json (result: "fail", deficiencies noted)
  2. Create a separate safety incident via the safety-management skill → writes to safety-log.json
  3. Cross-reference the inspection ID in the safety incident record
  4. The safety-management skill handles TRIR calculation, OSHA compliance, and corrective action lifecycle

Extended reference: Detailed examples, templates, scoring rubrics, and best practices are in references/skill-detail.md.

Install via CLI
npx skills add https://github.com/mgoodman60/foreman-os-plugin --skill inspection-tracker
Repository Details
star Stars 1
call_split Forks 0
navigation Branch main
article Path SKILL.md