name: ot-incident-resolution version: 1.0.0 description: Generate OT incident resolution notes with safety considerations, containment procedures, and remediation steps for industrial control systems and operational technology environments author: Happy Technologies LLC tags: [otsm, ot, incident-resolution, industrial, ics, safety, scada, containment] platforms: [claude-code, claude-desktop, chatgpt, cursor, any] tools: mcp: - SN-NL-Search - SN-Query-Table - SN-Read-Record rest: - /api/now/table/sn_ot_incident - /api/now/table/sn_ot_vulnerability - /api/now/table/cmdb_ci_ot_device - /api/now/table/sn_si_incident - /api/now/table/sys_journal_field - /api/now/table/change_request native: - Bash complexity: advanced
estimated_time: 15-30 minutes
OT Incident Resolution
Overview
This skill provides a structured approach to generating resolution notes for Operational Technology (OT) incidents in ServiceNow. OT incidents require specialized handling due to the safety-critical nature of industrial control systems (ICS), SCADA systems, and operational technology environments where cyber-physical consequences can impact human safety and critical infrastructure.
Key capabilities:
- Document incident containment actions taken for OT/ICS environments
- Capture safety impact assessments and physical consequence analysis
- Record remediation steps with safety validation checkpoints
- Track affected OT devices, zones, and network segments
- Generate resolution notes that satisfy regulatory and audit requirements
- Ensure operational safety protocols are documented throughout the resolution lifecycle
When to use: When resolving OT security incidents, ICS anomalies, SCADA system alerts, or any incident affecting operational technology environments where safety and operational continuity are paramount.
Prerequisites
- Roles:
sn_ot_admin,sn_ot_analyst,sn_si_analyst, oritilwith OT scope access - Access: Read/write access to
sn_ot_incident,sn_ot_vulnerability,cmdb_ci_ot_device, andsys_journal_fieldtables - Plugins: Operational Technology (com.snc.ot) and Security Incident Response (com.snc.si) must be active
- Knowledge: Understanding of ICS/SCADA systems, Purdue Model network segmentation, and industrial safety protocols
Procedure
Step 1: Retrieve OT Incident Details
Fetch the OT incident record with all classification and impact fields.
Using MCP:
Tool: SN-Read-Record
Parameters:
table_name: sn_ot_incident
sys_id: [INCIDENT_SYS_ID]
fields: sys_id,number,short_description,description,state,priority,severity,category,subcategory,assigned_to,assignment_group,opened_at,resolved_at,affected_ci,cmdb_ci,location,impact,urgency,business_impact,safety_impact,ot_zone,attack_vector,containment_status,resolution_code,resolution_notes,close_notes
If searching by number:
Tool: SN-Query-Table
Parameters:
table_name: sn_ot_incident
query: number=OT0012345
fields: sys_id,number,short_description,description,state,priority,severity,category,subcategory,assigned_to,assignment_group,opened_at,affected_ci,cmdb_ci,location,impact,safety_impact,ot_zone,attack_vector,containment_status
limit: 1
Using REST API:
GET /api/now/table/sn_ot_incident?sysparm_query=number=OT0012345&sysparm_fields=sys_id,number,short_description,description,state,priority,severity,category,subcategory,assigned_to,assignment_group,opened_at,affected_ci,cmdb_ci,location,impact,safety_impact,ot_zone,attack_vector,containment_status&sysparm_limit=1&sysparm_display_value=true
Step 2: Retrieve Affected OT Devices
Identify all OT devices impacted by the incident.
Using MCP:
Tool: SN-Query-Table
Parameters:
table_name: cmdb_ci_ot_device
query: sys_id=[AFFECTED_CI_SYS_ID]
fields: sys_id,name,sys_class_name,device_type,manufacturer,model_id,firmware_version,ip_address,mac_address,location,operational_status,install_status,ot_zone,protocol,serial_number,asset_tag,support_group,safety_critical
limit: 1
For all devices in the affected zone:
Tool: SN-Query-Table
Parameters:
table_name: cmdb_ci_ot_device
query: ot_zone=[ZONE_VALUE]^operational_status=1
fields: sys_id,name,device_type,manufacturer,ip_address,ot_zone,safety_critical,operational_status
limit: 50
Using REST API:
GET /api/now/table/cmdb_ci_ot_device/{AFFECTED_CI_SYS_ID}?sysparm_fields=sys_id,name,sys_class_name,device_type,manufacturer,model_id,firmware_version,ip_address,ot_zone,protocol,safety_critical&sysparm_display_value=true
GET /api/now/table/cmdb_ci_ot_device?sysparm_query=ot_zone=[ZONE_VALUE]^operational_status=1&sysparm_fields=sys_id,name,device_type,manufacturer,ip_address,safety_critical&sysparm_limit=50&sysparm_display_value=true
Step 3: Assess Safety Impact
Review and document the safety impact of the incident on physical operations.
Using MCP:
Tool: SN-Query-Table
Parameters:
table_name: sys_journal_field
query: element_id=[INCIDENT_SYS_ID]^element=work_notes^valueLIKEsafety^ORDERBYDESCsys_created_on
fields: value,sys_created_on,sys_created_by
limit: 20
Using REST API:
GET /api/now/table/sys_journal_field?sysparm_query=element_id=[INCIDENT_SYS_ID]^element=work_notes^valueLIKEsafety^ORDERBYDESCsys_created_on&sysparm_fields=value,sys_created_on,sys_created_by&sysparm_limit=20
Step 4: Review Related Vulnerabilities
Check if the incident is linked to known OT vulnerabilities.
Using MCP:
Tool: SN-Query-Table
Parameters:
table_name: sn_ot_vulnerability
query: affected_ci=[AFFECTED_CI_SYS_ID]^ORDERBYDESCseverity
fields: sys_id,number,short_description,severity,state,cve_id,affected_ci,risk_score,remediation_status,published_date,vendor_advisory
limit: 10
Using REST API:
GET /api/now/table/sn_ot_vulnerability?sysparm_query=affected_ci=[AFFECTED_CI_SYS_ID]^ORDERBYDESCseverity&sysparm_fields=sys_id,number,short_description,severity,state,cve_id,risk_score,remediation_status,vendor_advisory&sysparm_limit=10&sysparm_display_value=true
Step 5: Document Containment Actions
Record the containment measures taken to isolate the threat.
Using MCP:
Tool: SN-Query-Table
Parameters:
table_name: sys_journal_field
query: element_id=[INCIDENT_SYS_ID]^element=work_notes^valueLIKEcontainment^ORDERBYsys_created_on
fields: value,sys_created_on,sys_created_by
limit: 20
Using REST API:
GET /api/now/table/sys_journal_field?sysparm_query=element_id=[INCIDENT_SYS_ID]^element=work_notes^valueLIKEcontainment^ORDERBYsys_created_on&sysparm_fields=value,sys_created_on,sys_created_by&sysparm_limit=20
Step 6: Check Related Change Requests
Identify any change requests created for remediation activities.
Using MCP:
Tool: SN-Query-Table
Parameters:
table_name: change_request
query: parent=[INCIDENT_SYS_ID]^ORcorrelation_id=[INCIDENT_NUMBER]
fields: sys_id,number,short_description,state,type,risk,category,assigned_to,start_date,end_date,approval
limit: 10
Using REST API:
GET /api/now/table/change_request?sysparm_query=parent=[INCIDENT_SYS_ID]^ORcorrelation_id=[INCIDENT_NUMBER]&sysparm_fields=sys_id,number,short_description,state,type,risk,category,assigned_to,start_date,end_date,approval&sysparm_limit=10&sysparm_display_value=true
Step 7: Build the Resolution Notes
Assemble comprehensive resolution documentation:
=== OT INCIDENT RESOLUTION NOTES ===
Incident: [number] | Priority: [priority] | Severity: [severity]
Category: [category] / [subcategory]
Opened: [opened_at] | Resolved: [resolved_at]
Duration: [resolution_duration]
AFFECTED ENVIRONMENT:
OT Zone: [ot_zone] (Purdue Level [level])
Primary Device: [device_name] ([device_type])
Manufacturer: [manufacturer] | Firmware: [firmware_version]
Protocol: [protocol] | IP: [ip_address]
Safety Critical: [YES/NO]
Additional Affected Devices: [count]
SAFETY IMPACT ASSESSMENT:
Physical Safety Risk: [None/Low/Medium/High/Critical]
Personnel Hazard: [description]
Environmental Impact: [description]
Process Safety Impact: [description]
Safety Systems Affected: [SIS/ESD/fire suppression status]
INCIDENT SUMMARY:
[description of what occurred, attack vector, initial detection]
CONTAINMENT ACTIONS:
1. [timestamp] - [action taken] - [performed by]
2. [timestamp] - [action taken] - [performed by]
3. [timestamp] - [action taken] - [performed by]
Containment Status: [Contained/Partially Contained/Not Contained]
ROOT CAUSE:
[root cause analysis findings]
Related Vulnerability: [CVE if applicable]
REMEDIATION STEPS:
1. [step] - Status: [Complete/Pending]
Safety Validation: [validation performed]
2. [step] - Status: [Complete/Pending]
Safety Validation: [validation performed]
CHANGE REQUESTS:
- [CHG number]: [description] - [status]
POST-RESOLUTION VERIFICATION:
[ ] Device operational status restored
[ ] Safety systems verified functional
[ ] Network segmentation confirmed
[ ] Monitoring alerts re-enabled
[ ] Operations team sign-off obtained
[ ] Regulatory notification completed (if required)
LESSONS LEARNED:
- [observation and recommendation]
- [process improvement suggestion]
Tool Usage
MCP Tools Reference
| Tool | When to Use |
|---|---|
SN-NL-Search |
Natural language search (e.g., "find critical OT incidents in Zone 3") |
SN-Query-Table |
Structured queries for incidents, devices, vulnerabilities, and work notes |
SN-Read-Record |
Retrieve specific incident or device records by sys_id |
REST API Reference
| Endpoint | Method | Purpose |
|---|---|---|
/api/now/table/sn_ot_incident |
GET | OT incident records |
/api/now/table/cmdb_ci_ot_device |
GET | OT device inventory |
/api/now/table/sn_ot_vulnerability |
GET | OT vulnerability records |
/api/now/table/sn_si_incident |
GET | Security incident correlation |
/api/now/table/sys_journal_field |
GET | Work notes and activity |
/api/now/table/change_request |
GET | Related change requests |
Best Practices
- Safety first: Always document safety impact assessment before technical remediation details
- Never patch without change control: OT environments require formal change management even for security patches
- Preserve forensic evidence: Document device states and network captures before containment actions alter evidence
- Coordinate with operations: OT incident response must involve plant/operations personnel, not just IT security
- Respect Purdue Model boundaries: Document which network zones were affected and ensure containment respects zone segmentation
- Verify safety systems: After remediation, explicitly verify that Safety Instrumented Systems (SIS) and Emergency Shutdown (ESD) systems are fully operational
- Document regulatory requirements: Note any mandatory reporting obligations (NERC CIP, IEC 62443, NIST SP 800-82)
- Include physical verification: Resolution of OT incidents often requires physical on-site verification, not just remote confirmation
Troubleshooting
"OT incident table not available"
Cause: The Operational Technology plugin is not installed or activated.
Solution: Verify that com.snc.ot plugin is active. Check if the OT module is licensed for your instance. The table may be sn_ot_incident or a custom extension.
"Device records missing OT-specific fields"
Cause: OT devices may be stored in base CMDB classes without OT extensions.
Solution: Check cmdb_ci_ot_device and its child classes (cmdb_ci_ot_plc, cmdb_ci_ot_rtu, cmdb_ci_ot_hmi). Some organizations use custom classes for OT equipment.
"Cannot find related vulnerabilities"
Cause: OT vulnerability data may not be synced or the affected_ci reference may use a different field.
Solution: Try querying sn_ot_vulnerability by device name or IP address instead of sys_id. Check if vulnerability data is imported from a third-party OT security tool.
"Safety impact fields are empty"
Cause: Custom safety assessment fields may not be populated, or the organization uses a separate safety management system. Solution: Check work notes for safety-related entries. Review any linked records in risk or safety management tables. Consult the safety officer for manual assessment documentation.
Examples
Example 1: PLC Firmware Exploit Resolution
Scenario: A programmable logic controller (PLC) in a manufacturing plant was compromised via a known firmware vulnerability.
Step 1 - Get incident:
Tool: SN-Query-Table
Parameters:
table_name: sn_ot_incident
query: number=OT0004521
fields: sys_id,number,short_description,state,severity,affected_ci,ot_zone,safety_impact,containment_status
limit: 1
Resolution Notes:
OT INCIDENT OT0004521 - RESOLVED
PLC Firmware Exploitation - Siemens S7-1500 (Zone 2)
Severity: High | Safety Impact: Medium
Duration: 8 hours | Containment: 45 minutes
AFFECTED DEVICE:
Siemens S7-1500 PLC | FW: V2.8.3 (vulnerable)
Zone 2 - Process Control | Safety Critical: YES
Controls: Batch mixing process Line 4
SAFETY ASSESSMENT:
- No personnel safety incident occurred
- Process was safely shut down via manual override
- SIS remained fully operational throughout
- No environmental release detected
CONTAINMENT:
1. 08:15 - Isolated PLC from OT network at Zone 2 switch
2. 08:30 - Engaged manual process control for Line 4
3. 08:45 - Confirmed no lateral movement to other PLCs
4. 09:00 - Preserved PLC memory dump for forensics
REMEDIATION:
1. Applied firmware update V2.9.1 (CVE-2026-1234 fix) - COMPLETE
2. Reset all PLC credentials and certificates - COMPLETE
3. Updated firewall rules at Zone 2/3 boundary - COMPLETE
4. Verified PLC logic integrity against golden image - COMPLETE
5. Restored automated process control - COMPLETE
6. Operations sign-off obtained - COMPLETE
CHANGE REQUEST: CHG0098765 - Emergency firmware update
Example 2: SCADA Network Anomaly Resolution
Scenario: Anomalous network traffic detected on SCADA communication channels.
OT INCIDENT OT0004533 - RESOLVED
Anomalous Modbus Traffic on SCADA Network
Severity: Critical | Safety Impact: Low (monitoring only)
Duration: 12 hours
AFFECTED: 3 RTUs in Zone 1 (Water Treatment Facility)
Root Cause: Misconfigured network monitoring tool generating
excessive Modbus polling requests
CONTAINMENT: Disabled monitoring tool polling, verified RTU
operation unaffected.
REMEDIATION: Reconfigured monitoring tool with correct polling
intervals. Added Modbus traffic rate limiting at Zone 1 firewall.
LESSONS LEARNED: Network monitoring tools in OT environments
must be validated against OT protocol specifications before
deployment to prevent false positives and operational disruption.
Related Skills