Orchestrate data-driven Siemens TIA Portal workflows: read structured data from CSV/Excel files, generate STL/AWL code via the siemens-awl-stl-programmer skill, and apply changes to a live TIA Portal project. Trigger when the user asks to import, generate, sync, or batch-apply PLC blocks, tags, devices, or data blocks from a spreadsheet or CSV source — or to export existing TIA Portal project data into a file.

chewcw By chewcw schedule Updated 4/7/2026

name: siemens-tia-portal-integrator description: > Orchestrate data-driven Siemens TIA Portal workflows: read structured data from CSV/Excel files, generate STL/AWL code via the siemens-awl-stl-programmer skill, and apply changes to a live TIA Portal project. Trigger when the user asks to import, generate, sync, or batch-apply PLC blocks, tags, devices, or data blocks from a spreadsheet or CSV source — or to export existing TIA Portal project data into a file. metadata: version: "1.1"

Siemens TIA Portal Integrator Skill

Overview

This skill bridges three layers:

Layer Purpose
File I/O Read/write CSV and Excel source files
Code Generation Produce compilable STL/AWL source via siemens-awl-stl-programmer skill
Project Automation Apply changes to a live TIA Portal project

Prerequisite: This skill requires TIA Portal automation capability (e.g., TIA Portal Openness API or MCP server). The agent is responsible for discovering and using the appropriate tools for its environment.

Always invoke the siemens-awl-stl-programmer skill when the workflow involves generating or modifying STL/AWL block source. Validate data completely before applying any changes to the project.


Skill Map

siemens-tia-portal-integrator/
│
├── SKILL.md                         ← you are here (index + quick-reference)
│
├── references/
│   ├── scripts/                     ← Helper scripts for file I/O and validation
│   │   ├── read_csv.md
│   │   ├── read_excel.md
│   │   ├── list_sheets.md
│   │   ├── validate_columns.md
│   │   └── write_excel_summary.md
│   ├── patterns/                    ← Workflow patterns
│   │   ├── import-tags-csv.md       ← Pattern A: Import tags from CSV/Excel
│   │   ├── import-devices-excel.md  ← Pattern B: Import devices from Excel
│   │   ├── generate-blocks-excel.md ← Pattern C: Generate blocks from Excel spec
│   │   └── export-blocks-excel.md   ← Pattern D: Export blocks to Excel
│   └── examples/                    ← Full conversation examples
│       ├── example-tag-import.md
│       ├── example-device-import.md
│       ├── example-block-generation.md
│       └── example-block-export.md

Validation Rules

Apply these rules before creating any data in TIA Portal:

Tag names

  • Max 24 characters; first character must be a letter or underscore
  • Allowed: letters, digits, underscore — no spaces or special characters

Data types

  • Bool Byte Word DWord Int DInt Real LReal Time Char String
  • Capitalisation is exact — use these spellings

Logical addresses

  • Inputs: %I<byte>.<bit> or %IW<byte>
  • Outputs: %Q<byte>.<bit> or %QW<byte>
  • Memory: %M<byte>.<bit> or %MW<byte> or %MD<byte>

Order numbers

  • Example: 6ES7 516-3AN02-0AB0
  • Pattern: [Family 4 chars][Space][Article]-[SubArticle]-[Variant]

Block names

  • Max 24 characters; no special characters except underscore; unique within the device

Workflow Patterns

Choose the pattern that matches the user's request:

Pattern File Trigger
A — Import tags references/patterns/import-tags-csv.md "Import tags from CSV/Excel"
B — Import devices references/patterns/import-devices-excel.md "Import devices from Excel"
C — Generate blocks references/patterns/generate-blocks-excel.md "Generate blocks from spreadsheet"
D — Export blocks references/patterns/export-blocks-excel.md "Export blocks to Excel"

General Workflow Checklist

For any import/generate workflow, follow this sequence:

  • Step 1: Read source file — Read the CSV or Excel file containing the data
  • Step 2: Validate columns — Ensure required columns exist; map aliases to canonical names
  • Step 3: Verify TIA Portal session — Confirm a project is open and accessible
  • Step 4: Resolve target — Identify the target device, tag table, or block destination
  • Step 5: Pre-validate — Check catalog validity, duplicates, naming rules
  • Step 6: Apply changes — Create/modify data in the project; continue on single failures
  • Step 7: Save — Save the project after every successful batch
  • Step 8: Compile — Compile software after block changes
  • Step 9: Report — Summarize created/failed/skipped with details

General Best Practices

  1. Verify session first — confirm TIA Portal is accessible before any write operation.
  2. Validate before writing — run column validation and catalog checks before creating any data.
  3. Ask on ambiguity — if a requirement or target (device, sheet, table, mapping, action) is unclear or missing, ask the user before proceeding; do not assume.
  4. One operation per item — process items individually; no bulk payloads.
  5. Save after each batch — save the project after every successful write batch.
  6. Compile after block changes — compile software after uploading block sources.
  7. Delegate code generation — never write AWL inline; invoke siemens-awl-stl-programmer skill.
  8. Continue on single failures — collect all failures and report at the end, do not abort early.
Install via CLI
npx skills add https://github.com/chewcw/agent-skills --skill siemens-tia-portal-integrator
Repository Details
star Stars 4
call_split Forks 1
navigation Branch main
article Path SKILL.md